Project

General

Profile

Activity

From 2008-03-22 to 2008-04-20

2008-04-20

23:58 Feature #25 (Closed): Full featured command line editing
Support for home, end, up, down, ctrl-u, ctrl-w, del, delete. Up and Down should access a command-line history Hamish
23:52 Bug #16: Extra line is seen after every enter
Implementing this will require a cooked data processing mode - thus allowing telnet option processing in serial-data-... Hamish
23:35 Bug #16: Extra line is seen after every enter
This is due to the telnet end of line processing - Telnet specifies that end of line will either be CR LF or CR NUL, ... Hamish
23:37 Bug #19: more than one connection causes wierdness
There is less weirdness here now, but it is still not actually accepting more than one connection. The framework has... Hamish
23:34 Bug #17 (Closed): No telnet option processing is done
Telnet option processing was added in commit:"08ceb73b". This still needs hooking into the serial-data-pump Hamish
23:32 Feature #21: Listen port needs to be configurable
Implemented a console-mode command-line option for this, but not the whole option processing that I was looking for Hamish
23:31 Feature #23: Support "send break" sequence
the telnet option processing framework now exists, but it is not hooked up to anything useful, nor it it reachable fr... Hamish

2008-04-18

18:32 Feature #23 (Closed): Support "send break" sequence
Once we support telnet option processing, it would be good to send a serial break sequence when a telnet send break i... Hamish
18:13 Feature #22 (New): Visible progress indicators displayed on the console
In order to provide feedback and reassure the end user that something is happening, it would be nice to have some fee... Hamish
16:56 Feature #21 (New): Listen port needs to be configurable
Currently, the port that this application will listen on is hard-coded. There should be the ability to configure thi... Hamish
15:55 Bug #18 (Closed): menu interpreter cannot handle receiving CR LF
Hamish
15:51 Bug #20 (Closed): cannot return to menu
Once a connection to the serial port is established, there is no method for returning to the original menu Hamish
15:50 Bug #19 (Closed): more than one connection causes wierdness
If the first connection is in the menu and a new connection arrives, it hangs.
If the first connection is talking ...
Hamish

2008-04-17

22:47 Bug #18 (Closed): menu interpreter cannot handle receiving CR LF
When using telnet in linemode, the telnet process appears to send both a CR and a LF to the remote system. This is n... Hamish
22:44 Bug #17 (Closed): No telnet option processing is done
Connecting to the server using a standard telnet client results in some garbage as the client attempts option processing Hamish
22:42 Bug #16 (Closed): Extra line is seen after every enter
pressing enter appears to be interpreted by the serial device as two enters. Hamish
 

Also available in: Atom